How the inspection level finder decides
NFPA 211, the national standard for chimneys, fireplaces and vents, describes three levels of chimney inspection. They differ in how much of the chimney the inspector has to reach, and the choice between them depends on what has happened to the house and the chimney since the last inspection, not on how thorough you would like the visit to be.
The finder asks about the events the standard ties to each level. A sale, a change to the chimney system and damage from a fire or storm each point to Level 2; signs of hidden damage that an earlier inspection could not reach point to Level 3; and a chimney in steady, unchanged use stays at Level 1. The highest level any answer calls for is the one it shows.
Treat the answer as a starting point for the conversation rather than the last word. The technician confirms the level on site and can move up a level when the findings call for it. Our guide to chimney inspection levels walks through each one in detail, and you can book a chimney inspection at any level.

Why so many Scarsdale chimneys end up at Level 2
More than half of Scarsdale's homes were built before 1950, and many of their chimneys have outlived at least one change of heating equipment. When an old oil burner gives way to a gas boiler, or an open fireplace gets a wood or gas insert, the flue often has to be relined to suit the new appliance, and NFPA 211 treats that kind of change as a reason for a Level 2 inspection.
Home sales are the other common trigger. A buyer inherits a chimney with a history no one in the transaction has seen from the inside, and a camera scan of every flue is the practical way to see it before closing. Sellers can make the same scan before listing, so a cracked tile or an unlined flue shows up on their schedule rather than in the middle of a negotiation.